Safety Fuse

Safety Fuse

img

Safety Fuse is one of the accessories used for blasting explosives in conjunction with an ordinary detonator; it may be defined as a device, which conveys flame at a control, predetermined burning speed to ignite the explosives charge in detonator.

In the view of a enormous risk involved in carrying out blasting operation in open cast coal mines, quarries or in demolishing jobs, two types of firing devices are used, to ensure safety of the personnel handling the operation, blasting is done with either electrically ignited detonator by remote control operation or with detonator ignited by a flame carried by a safety fuse cord at regulated speed without any lateral propogation of sparks or flame.

Saftey fuse essentially consists of a core of bright hard well granulated gunpower grains, free from dust & grit, adequately enveloped by cotton & jute textiles yarns and intermediate water proofing material. The water proofing material are designed in such a way that it would not contribute for any undue sparks emitting from the external surface and also would not cause any lateral ignition.

Name Construction Colour Diameter
in mm
Burning
speed
Sec/mts
Packing Best Before Suggested for
use in
Glue Sump
Fuse
Gun Powder Core in Jute, Bitumen shall be in uniform thickness Blue 4.8 ± 0.3 100 - 120 150 Nos
10 Mts Coil
1500 mt / Case
2 Years from
date of Mfg
Normal Dry
Conditions
Glue Plastic
Fuse
Gun Powder Core wraped in two Jute layers with Bitumen & Polythene Coating Blue 4.8 - 5.2 110 ± 10 10mts Coil
1500 mt / Case
2 Years from
date of Mfg
Very Wet and
damp
Condition
Alisa Saftey
Fuse
Gun Powder Core in Jute, Bitumen with antistatic, Poly Coating, with uniform thickness free from visible flaws Yellow 5 ± 0.2 120 - 145 170 mts
per reel / case
2 Years from
date of Mfg
For Export and
24 hours under
Water Condition

Note:

  • Cord Load - 4.2 gms / Meters ± 10%
  • Cap Sensitive - 25 mm.
  • Lateral Transmission of flame - absent
  • Storage - Safety fuse should in dry place protected from excessive heat or extreme cold and should not be exposed to oil or other solvents.